What is a COA? How peptide purity is tested
A certificate of analysis (COA) is the lab report for one batch. The World Health Organization (WHO) describes it as a document that “lists tests performed on a particular sample with the results obtained and the acceptance criteria applied”, followed by whether the sample complies with the specification[1]. For peptides, the manufacturer Bachem calls analytical HPLC “the standard method for peptides” for purity, and determines molecular weight by mass spectrometry[2].
What a COA is
The WHO publishes a model certificate of analysis for use by quality control laboratories and in trade[1]. In it, a COA lists the tests performed on a sample, the results and the acceptance criteria, and ends with whether the sample complies with the specification. The WHO adds that a COA “is usually prepared for each batch”[1].
Peptide makers work the same way. Bachem says that a selection of its test results appears on the Analytical Data Sheet (ADS) or Certificate of Analysis (CofA) that it makes available to customers who buy its products[2]. The abbreviation differs: the WHO writes CoA, Bachem writes CofA, and this site writes COA.
Bachem sums up what quality control has to answer in four questions: is it the desired product, how pure is it, what by-products does it contain, and how high is the product content[2]. The rest of this page takes them in turn.
What “99% purity” means
The purity figure on a peptide COA usually comes from analytical high-performance liquid chromatography (HPLC). Bachem calls it “the standard method for peptides”. Purity is typically assessed by UV detection at 210–220 nm, where “the area of the main peak in relation to the total area of all peaks reflects the peptide purity”[2].
So a purity of 99% means that the main peak, the wanted peptide, makes up 99% of the total peak area. Bachem’s answer to “What does HPLC purity mean?” puts it the same way: the percentage of the requested peptide in relation to all the material absorbing at 220 nm, that is, “the desired product, peptidic by-products and other impurities”[3].
HPLC purity therefore covers the material the detector records. Water and the acids bound to a peptide are, in Bachem’s words, “not measured by the same methods used to determine the purity of the desired product”[2]. The part on peptide content below explains why that matters.
One batch can carry more than one purity figure. Bachem’s data sheet for a peptide can list purity determined by HPLC as “up to 3 values obtained in different buffer systems”[3].
Identity: mass spectrometry
Purity says how much of the sample is the main peak. Identity is a separate question, which Bachem puts as “Is it, in fact, the desired product?”[2]
Bachem says that if it is the desired product, the measured values should correspond to those in the literature or to those obtained for a reference sample, and that “The molecular weight is determined by mass spectrometry.”[2] Bachem obtains its mass spectra by ESI-MS, and routinely uses MALDI-TOF and Q-TOF as well[3].
Bachem lists other identity tests too, among them co-elution with a reference sample by analytical HPLC, mainly for peptides, and amino acid analysis, which breaks the peptide down into its amino acids and, Bachem notes, “does not provide sequence information”[2].
Purity is not the same as peptide content
The weighed powder is not all peptide. Bachem says the gross weight of a peptide sample “comprises the weight of the peptide, counter-ions, and adhered water”[3]. Lyophilized products typically contain trace amounts of residual solvents and/or water, and most peptides also contain trifluoroacetic acid (TFA) or acetic acid, firmly bound to the peptide as a salt[2]. TFA “cannot be completely removed due to salt formation”[2].
The share that is peptide is the net peptide content (NPC). Bachem defines it as the fraction of peptidic material, meaning the requested peptide and the peptidic impurities, relative to counter-ions and residual water[3], and says that “NPC and purity are not equivalent, because the former includes peptidic contaminants”[2].
Bachem gives a simple example: a sample with an NPC of 85% and a gross weight of 1 mg holds 0.85 mg of peptide[3]. In another of its examples, a bradykinin acetate salt has an HPLC purity of 98.7% and an NPC of 85.0%[3]. The two figures measure different things, so both can be true of the same batch.
NPC is measured with methods other than HPLC. Among them Bachem lists elemental analysis, where the nitrogen content is a measure of the peptide content, and the Karl Fischer method for water[2]. Bachem adds that a low NPC must be expected for peptides with a large proportion of basic amino acids, even if they are extremely pure, and for hydrophilic peptides, which can absorb considerable amounts of moisture[2].
Bachem says “A selection of the obtained results” appears on its data sheet or COA[2], so a report may show purity without peptide content. In that case the purity figure does not say how much of the powder is water or counter-ions.
What the impurities are
Bachem says that not all impurities can be removed by a single preparative HPLC run, and that a few peptidic contaminants usually remain, mostly deletion sequences, “peptides lacking one or more amino acids of the target sequence”[3]. Because they differ only slightly in polarity, their removal may fail[3].
Purity can also vary from batch to batch. In Bachem’s example, a peptide ordered at 80% purity can range from 80% to 100%, and the variability is more noticeable at lower purity levels[2]. Batches with low purity may contain peptidic by-products that differ in proportion and structure, and in some cases these by-products can interfere with assays[2].
This is why a COA belongs to one batch. A report for another batch does not describe the vial in hand.
How to read a COA
The WHO model lists what a COA should include[1]. The main items, in plain words:
- The name and address of the laboratory that issued it, and an identification number for the certificate[1].
- The name of the sample, its batch number, its expiry or retest date and, if available, its date of manufacture[1].
- The name and address of the original manufacturer and, if the product is supplied by a repacker or trader, theirs too[1].
- The specifications and the test procedures used, with the acceptance criteria (limits)[1].
- The results of every test, compared with the acceptance criteria. Results of tests done by subcontractors should be identified as such[1].
- A conclusion on whether the sample was within the limits of the specification[1].
- The date, and the signature of the head of the laboratory or another authorized person[1].
For a peptide, Bachem’s data sheet can list the lot number, the name and sequence, the molecular formula and relative molecular mass, the appearance, the molecular mass obtained by mass spectrometry, amino acid analysis, HPLC purity, and an “assay” of nitrogen content by elemental analysis, which corresponds to the net peptide content[3].
Two more points from the WHO model. When a repacker or trader issues a new certificate, it should show the name and address of the laboratory that performed the tests and of the original manufacturer, with a copy of the manufacturer’s COA attached[1]. And a laboratory accredited to ISO/IEC 17025 should refer to that accreditation on the COA, if it relates to the analysis[1].
Questions to ask of any peptide COA, drawn from the points above:
- Does the batch number match the vial?
- Which laboratory did the testing, and when was the report signed?
- Is there a purity result, with its method and its limit?
- Is there a mass spectrometry result that matches the expected molecular mass?
- Does it show net peptide content, or only purity?
NorthSpecLabs lab reports
Lab reports for our products are being added and will be posted on the lab reports (COA) page before orders open.
Every product on this site is sold for laboratory research use only. NorthSpecLabs does not provide dosing, administration or medical advice.
Questions and answers
What is a COA?
A certificate of analysis: the lab report for one batch. It lists the tests performed, the results, the acceptance criteria (limits) and whether the batch met them.
What does 99% purity mean on a peptide COA?
When the figure comes from HPLC, it means the main peak, the wanted peptide, makes up 99% of the total area of all peaks recorded by the UV detector. It does not cover water or counter-ions such as TFA.
What is HPLC?
High-performance liquid chromatography. The peptide manufacturer Bachem calls analytical HPLC the standard method for measuring peptide purity.
Why is mass spectrometry on a COA?
To check identity, that the batch is the intended peptide. Mass spectrometry determines the molecular weight, which should correspond to the expected value.
Is purity the same as net peptide content?
No. HPLC purity compares the wanted peptide with peptide-like impurities. Net peptide content is the share of the powder that is peptide rather than counter-ions and water. In one of Bachem’s examples, a peptide has 98.7% HPLC purity and 85.0% net peptide content.
Does NorthSpecLabs provide dosing or usage instructions?
No. Products are sold for laboratory research use only. NorthSpecLabs does not provide dosing, administration or medical advice.
References
- World Health Organization. Model certificate of analysis. Annex 4 in: WHO Expert Committee on Specifications for Pharmaceutical Preparations, fifty-second report. WHO Technical Report Series, No. 1010, 2018. Read November 9, 2026. Open source
- Bachem. Quality Control of Amino Acids & Peptides: A Guide. Bachem Knowledge Center. Read November 9, 2026. Open source
- Bachem. FAQ: What does net peptide content mean? Read November 9, 2026. Open source
Last reviewed: November 9, 2026. This page summarises published sources. It is not medical or legal advice.
For laboratory research use only. Not for human or veterinary use. NorthSpecLabs does not provide dosing, administration or medical advice.